Motors supposed to do some work and two important values define how powerful the motor is. It is motor speed and torque the turning force of the motor. Output mechanical power of the motor could be calculated by using the following formula: P out = τ * ω. where P out output power
Electric Motor Calculator Calculate amps, hp and kVA . Sponsored Links . The calculators below can be used to calculate electric motor amps, AC Active, Reactive and Apparent Power Real, imaginary and apparent power consumption in AC circuits; Asynchronous Induction Motors Electrical Data Electrical motor data nominal current,
Given torque in any unit, and speed in rpm, calculate power in watts or hp.
For a 1-phase supply with power rating in kilowatt (kW): For a 1-phase supply with power rating in horsepower (hp): Note that the motor rated full load current is specified on the motor datasheet and stamped on the motor nameplate. However, this calculator is useful when only the motor rating is available and an estimate of the current is required.
Calculate three-phase motor power consumption by multiplying amps by volts by the square root of three (W = AV(sqrt 3). For example, if the motor is drawing 30 amps at 250 volts, you have 30 x 250 x sqrt 3 (about 1.73) = 12,975 watts). Convert watts to kilowatts by dividing the number of watts by 1,000.
Electric Motor Wiring 480 Volt Electrical motor wiring data NEMA amps, starter size, HMCP size for motors ranging 1/2 to 500 hp; Electrical Induction Motors Synchronous Speed The speed at which an induction motor operates depends on the input power frequency and the number of electrical magnetic poles in the motor
If you can measure the voltage and amps flowing into the motor leads: (single phase) Amps x volts = VA, assume the Power factor is 0.8 so the KW is (VA/1000) x 0.8 on three phase, assuming balanced line currents, multiply by sq rt 3 (1.732). That
Shaft Pump Power. The shaft power the power required transferred from the motor to the shaft of the pump depends on the efficiency of the pump and can be calculated as. P s(kW) = P h(kW) / η (3) where . P s(kW) = shaft power (kW) η = pump efficiency. Online Pump Calculator SI-units
Amps to kW calculator * Use e for scientific notation. E.g: 5e3, 4e-8, 1.45e12. DC kilowatts to amps calculation. The current I in amps (A) is equal to 1000 times the power P in kilowatts (kW), divided by the voltage V in volts (V):
If you can measure the voltage and amps flowing into the motor leads: (single phase) Amps x volts = VA, assume the Power factor is 0.8 so the KW is (VA/1000) x 0.8 on three phase, assuming balanced line currents, multiply by sq rt 3 (1.732). That
Shaft Pump Power. The shaft power the power required transferred from the motor to the shaft of the pump depends on the efficiency of the pump and can be calculated as. P s(kW) = P h(kW) / η (3) where . P s(kW) = shaft power (kW) η = pump efficiency. Online Pump Calculator SI-units
Power is consumed by a pump, fan or compressor in order to move and increase the pressure of a fluid. The power requirement of the pump depends on a number of factors including the pump and motor efficiency, the differential pressure and the fluid density, viscosity and flow rate. This article provides relationships to determine the required
Motor Sizing. Proper sizing and selection of a motor for your equipment is key to ensuring performance, reliability and cost of the equipment. In addition to the information below for properly sizing a motor, Oriental Motor offers online motor sizing tools as well as assistance from our Technical Support staff.
An electrical motor with power 150 kW has power factor before improvement cosΦ = 0.75. For a required power factor after improvement cosΦ = 0.96 the capacitor correction factor is 0.58. The required KVAR capacity can be calculated as. Scientific Online Calculator . 12 20 .
The power factor correction capacitor should be connected in parallel to each phase load. The power factor calculation does not distinguish between leading and lagging power factors.
Power-Torque Torque (lb) = 63,025 x Power (HP) / Speed (RPM) Power (HP) = Torque (lb) x Speed (RPM) / 63,025. Torque (N.m) = 9.5488 x Power (kW) / Speed (RPM)
Charging Electrical Vehicles Voltage, Amps and Power EV Electrical Vehicle Charging Stations Power vs. Amps and Voltage AC vs. DS Single Phase vs. Three Phase; Electric Motors Power and Torque vs. Speed Speed of electrical motors output power and torque
Motor Efficiency is the efficiency of the motor. Brushed motor have around 75-80% efficiency and brushless motors have around 85-90% efficiency. Speed is the top speed of the calculation. This calculator provides an estimate of what size electric motor is necessary to propel a vehicle on flat ground or up an incline at a certain speed.
kW-kVA to Power factor calculation, formula, table, convert free. With this tool you can convert online from kW-kVA to Power factor automatically, easily, quickly and free. For more ease we show how to convert from kW-kVA to Power factor and show the formula that is used for the conversion and a table with the main conversions from kW-kVA to Power factor.
Angle between Supply Voltage and Load Current. The power factor always lies in a closed interval of -1 to +1. The power factor calculation can be done using a power triangle, the cosine of the angle between active power and apparent power is considered as power factor and it is same as the angle between supply voltage and load current.
In a motor, power is delivered to the load by converting electrical energy per the following laws of science. In electrical systems, voltage is the force required to move A true power calculation will work on any type of waveform regardless of the power factor Selecting Instruments for Electric Motor Power Measurement and Analysis.
3 Phase Induction Motor current calculator is used to calculate the rated and full load amperes of the motor. Enter the rated volts, amps, power, and efficiency to find the current flowing through the motor. The 3 phase Induction motor is popular for its efficiency and
Antriebe Elektro-Jet-Power ; about eCalc drive calculator. Since 2004 eCalc provides web-based quality services to simulate, calculate, Thereafter all visitors may use your motors for calculation. This will increase your visibility on the market considerable.
12-2-2017· A stepper motor is a popular type of synchronous motor because it allows for precise movements or "steps". This type of motor also produces a lot of torque given it size which is why it has found itself in a number of industrial applications. This tool is designed to calculate the maximum speed of a
The three-phase power calculator calculates the apparent, active and reactive power for three-phase AC systems. Parameters: The three phase power calculator
To find the input power to a direct drive motor used in temperzone equipment, this can be easily taken from our published fan curves as shown in the example below: Example 1 Direct Drive Motor Input Power to ISD 184KY @ 1000 l/sec @ 125Pa external static.
Motors Gears, Drives Ohm's Law Particle Contamination Power Equations Pressure Help Quick Formulas Research Links Temperature Conv t/c Reference RTD Reference Time Standards 3-Phase Equations LonWorks Carbon Dioxide
An electric motor’s nameplate or rated power is its output power, not its electric input power. Electric power consumption is rated power divided by motor efficiency. Rated power depends on class of motor (which considers intended duty). Industrial grade motors usually are rated for continuous duty.